RGE32Lb

RGE32L RCBO (hereafter simply referred to as breakers), the rated insulation voltage of the breakers is 300V. In the circuit of AC50Hz/60Hz, rated working voltage 230V or below, rated current from 15A to 32A, the breakers has function of protecting human body from electric shock and equipment from electrical leakage, and it can prevent fire caused by insulation problem of equipment. The breakers also has overload protection devices ,so as to protect the circuit and the power equipment against damage.
Service hotline+86-137-7773-8060 +86-577-89051920
Ask Ouote Now

GENERAL

RGE32L RCBO (hereafter simply referred to as breakers), the rated insulation voltage of the breakers is 300V. In the circuit of AC50Hz/60Hz, rated working voltage 230V or below, rated current from 15A to 32A, the breakers has function of protecting human body from electric shock and equipment from electrical leakage, and it can prevent fire caused by insulation problem of equipment. The breakers also has overload protection devices ,so as to protect the circuit and the power equipment against damage.

The breakers could be installed vertically or horizontally.

The breakers comply with the demands of the following standards:

EN/IEC61009-1: Residual current operated circuit breakers with integral overcurrent protection for household and similar uses(RCBOs)——Part1:General rules.

NORMAL SERVICE AND MOUNTING CONDTIONS

The ambient air temperature does not exceed +40℃ and its average over a period of 24h does not exceed +35℃,the lower limit of the ambient air temperature is -5℃.

The altitude of the site of installation does not exceed 2000m.

The relative humidity of the air does not exceed 50% at a maximum temperature of +40℃ , higher relative humidities may be permitted at lower temperature,e.g.90% at +20℃. Special measures may be necessary in cases of occasional condensation due to variations in temperature.

Pollution degree 2.

Installing category: III

There must be not any explosive medium, and there must be not any gas which would corrode metal or any conducting dust which would destory the insulation

The place would not be invaded by rain and snow. 


MAIN TECHNICAL PERFORMANCE INDEX

    Frame

30

    Type

RGE32La

RGE32Lb

    Pole&Element2PE22PE2
    Wiring system1Φ2W1Φ2W

    Rated current(A)                 In

15(16),20,30(32)

15(16),20,30(32)

    Rated insulation voltage(VAC)    Ui

300

300

    Rated impulse withstand vol(V)   Uimp

4000

4000

    Rated operational voltage (VAC)  Ue

230

230

    Rated ultimate short-circuit
    breaking ability      
(kA) Icu

    230V

1.5

2.5

    Operating short-circuit breaking ability Ics (%Icu)

50

50

    Rated residual  operating current(mA) I△nimage.png15,30image.png15,30
    Residual current off-time at I△n (sec)≯0.1≯0.1
    Protective function    Electric leakage

    Overload

    Short-circuit

If the user needs short-circuit protection,  please specify when ordering.

    Short-circuit trip range

(10-20)In

(10-20)In

    Over-current tripping device    

Thermal-magnetic

Thermal-magnetic

    Comply standards

IEC60947-2

IEC60947-2

    Operational performance(times)

    Mechanical life85008500
    Electrical life15001500

Outline dimensions(mm)
弧形盖.jpg

    L

7070
    W3232
    H13636
    H23838
    H5151
    Connection    Screw
    Lug
    Mounting(standard)Screw fixedScrew fixed



OUTLINE AND MOUNTING DIMENSIONS


image.png