RGM3DC-800

Service hotline+86-137-7773-8060 +86-577-89051920
Ask Ouote Now

GENERAL

RGM3HU series moulded case circuit breaker (hereafter simply referred to as breakers), the maximum rated voltage of the breakers is DC1500V,and the maximum current is 800A.In the voltage of DC1500V,the maximum breaking capacity is 50kA,which can ensure reliable short-circuit protection of the system. 

The breakers could be installed vertically or horizontally.

The breakers comply with the demands of the following standards:

IEC60947-1 and GB14048.1  Low-voltage switchgear and controlgear——Part1:General rules.

IEC60947-2 and GB/T14048.2  Low-voltage switchgear and controlgear——Part 2:Circuit-breaker.


NORMAL SERVICE AND MOUNTING CONDTIONS

The ambient air temperature does not exceed +40℃ and its average over a period of 24h does not exceed +35℃,the lower limit of the ambient air temperature is -5℃.

The altitude of the site of installation does not exceed 5500m.

It is resistant to damp air(three-proof type).

It is resistant to the influence of salt fog and oil fog(three-proof type).

It is resistant to the influence of mold(three-proof type).

In a medium without explosion risk, and the medium is not enough to corrode the metal and destroy the insulation of the gas and conductive dust.

Note: The three-prevention products should be specially customized, please indicate TH.


MAIN TECHNICAL PERFORMANCE INDEX

   Frame800
   TypeRGM3DC-800
   Pole number23
   Rated current(A)                         In

700、800

   Rated insulation voltage(V)        Ui

1500
   Rated impulse withstand vol(V)  Uimp12
   Rated operational voltage (V)     Ue250/500750/10001250/15001250/1500
   Rated ultimate short-circuit  breaking ability      (kA) IcuH type653515

15(2P in series)

20(3P in series)

R type704020

20(2P in series)

23(3P in series)

   Operating short-circuit breaking ability  (kA) Ics100%Icu
   Wiring mode

Up incoming and Down outcoming(2P)

Down incoming and Up outcoming(2P)

Up incoming and Up outcoming(3P)

Down incoming and Down outcoming(3P)

   Arc-over distance(mm)≯50(Zero arc with arcing cover)
   Allowable ambient temperature-40~+70℃

   Levels of protection

IP20
   Transient Action value10ln
   Comply standards

IEC60947-2

  Operational performance (times)

Mechanical life

5000
Electrical life1000
1000700500
   Outline dimensions(mm)image.pngL
250
W124182
H165
   Shunt release
   Auxiliary contact
   Alarm contact
  Turning handle mechanism
   Power-driven mechanism



CONTACT FORM

Please fill out the below and we will get back to you as soon as possible.
+86-137-7773-8060
Quote Now
rigan@ruiguangelec.com